Data for the design of a Vertical Take Off plane

using electric Ducted Fans

Fred Jordan,jordan@ltssg3.epfl.ch

The data below have been found only on the internet. They present various motor/fan/battery configuration in term of thrust & weight of a vertical take off plane. If you have any comment or experience regarding this kind of project or the use of high drain currents on type "R" battery, let me know ! Other people are working on the same idea (and were working before me), have a look there !

Reference

Grams

FFrancs

Motor

Speed 480 Turbo 7.2V

120

132

Fan

MiniFan 480

72

240

Number of Fan

4

288

Total Fan

768

1488

Thrust

320

Eff. Thrust per fan

128

Total Eff. Thrust

512

Total Thrust

1280

Element

1000 SCR

41

Number per Pack

7

287

Number of Pack

1

287

Total Battery

297

Servo

HS 80

18

Receiver

30

Total RC

102

Total Weight

1167

Total Payload

113

Current per Motor

11.6

Current per Pack

46.4

Reference

Grams

FFrancs

Motor

Speed 400 6V.

73

60

Fan

MiniFan 480

72

240

Number of Fan

4

288

Total Fan

580

1200

Thrust

200

Eff. Thrust per fan

55

Total Eff. Thrust

220

Total Thrust

800

Element

1000 SCR

41

Number per Pack

7

287

Number of Pack

1

287

Total Battery

297

Servo

HS 80

18

Receiver

30

Total RC

102

Total Weight

979

Total Payload

-179

Current per Motor

6.6

Current per Pack

26.4

Reference

Grams

FF

Motor

Speed 500 Race

164

150

Fan

EcoFan II

85

360

Number of Fan

4

340

Total Fan

996

2040

Thrust

470

Eff. Thrust per fan

221

Total Eff. Thrust

884

Total Thrust

1880

Element

1000 SCR

41

Number per Pack

7

287

Number of Pack

2

574

Total Battery

594

Servo

HS 80

18

Receiver

30

Total RC

102

Total Weight

1692

Total Payload

188

Current per Motor

22.7

Current per Pack

45.4

Reference

Grams

FF

Motor

Speed 500 Compet.

196

150

Fan

EcoFan II

85

360

Number of Fan

4

340

Total Fan

1124

2040

Thrust

570

Eff. Thrust per fan

289

Total Eff. Thrust

1156

Total Thrust

2280

Element

1000 SCR

41

Number per Pack

7

287

Number of Pack

2

574

Total Battery

594

Servo

HS 80

18

Receiver

30

Total RC

102

Total Weight

1820

Total Payload

460

Current per Motor

24.5

Current per Pack

49.0

Reference

Grams

FF

Motor

Speed 600 7.2 V.

198

100

Fan

EcoFan II

85

360

Number of Fan

4

340

Total Fan

1132

1840

Thrust

670

Eff. Thrust per fan

387

Total Eff. Thrust

1548

Total Thrust

2680

Element

1000 SCR

41

Number per Pack

10

410

Number of Pack

2

820

Total Battery

840

Servo

HS 80

18

Receiver

30

Total RC

102

Total Weight

2074

Total Payload

606

Current per Motor

23.8

Current per Pack

47.6

Reference

Grams

FF

Motor

Ultra 2000/5 Mod.

640

1500

Fan

RK740E

140

900

Number of Fan

4

560

Total Fan

3120

9600

Thrust

2430

Eff. Thrust per fan

1650

Total Eff. Thrust

6600

Total Thrust

9720

Element

1000 SCR

41

Number per Pack

30

1230

Number of Pack

4

4920

Total Battery

4960

Servo

HS 80

18

Receiver

30

Total RC

102

Total Weight

8182

Total Payload

1538

Current per Motor

40.0

Current per Pack

40.0

Reference

Grams

Ffrancs

Motor

Speed 480 Turbo 7.2V

120

132

Fan

MiniFan 480

72

240

Number of Fan

2

144

Total Fan

384

744

Thrust

320

Eff. Thrust per fan

128

Total Eff. Thrust

256

Total Thrust

640

Element

1000 SCR

41

Number per Pack

7

287

Number of Pack

1

287

Total Battery

297

Servo

HS 80

18

Receiver

30

Total RC

102

Total Weight

783

Total Payload

-143

Current per Motor

11.6

Current per Pack

23.2

Reference

Grams

FFrancs

Motor

Speed 400 6V.

73

60

Fan

MiniFan 480

72

240

Number of Fan

2

144

Total Fan

290

600

Thrust

200

Eff. Thrust per fan

55

Total Eff. Thrust

110

Total Thrust

400

Element

1000 SCR

41

Number per Pack

7

287

Number of Pack

1

287

Total Battery

297

Servo

HS 80

18

Receiver

30

Total RC

102

Total Weight

689

Total Payload

-289

Current per Motor

6.6

Current per Pack

13.2

Reference

Grams

FF

Motor

Speed 500 Race

164

150

Fan

EcoFan II

85

360

Number of Fan

2

170

Total Fan

498

1020

Thrust

470

Eff. Thrust per fan

221

Total Eff. Thrust

442

Total Thrust

940

Element

1000 SCR

41

Number per Pack

7

287

Number of Pack

1

287

Total Battery

297

Servo

HS 80

18

Receiver

30

Total RC

102

Total Weight

897

Total Payload

43

Current per Motor

22.7

Current per Pack

45.4

Reference

Grams

FF

Motor

Speed 500 Compet.

196

150

Fan

EcoFan II

85

360

Number of Fan

2

170

Total Fan

562

1020

Thrust

570

Eff. Thrust per fan

289

Total Eff. Thrust

578

Total Thrust

1140

Element

1000 SCR

41

Number per Pack

7

287

Number of Pack

1

287

Total Battery

297

Servo

HS 80

18

Receiver

30

Total RC

102

Total Weight

961

Total Payload

179

Current per Motor

24.5

Current per Pack

49.0

Reference

Grams

FF

Motor

Speed 600 7.2 V.

198

100

Fan

EcoFan II

85

360

Number of Fan

2

170

Total Fan

566

920

Thrust

670

Eff. Thrust per fan

387

Total Eff. Thrust

774

Total Thrust

1340

Element

1000 SCR

41

Number per Pack

10

410

Number of Pack

1

410

Total Battery

420

Servo

HS 80

18

Receiver

30

Total RC

102

Total Weight

1088

Total Payload

252

Current per Motor

23.8

Current per Pack

47.6

Reference

Grams

FF

Motor

Ultra 2000/5 Mod.

640

1500

Fan

RK740E

140

900

Number of Fan

1

140

Total Fan

780

2400

Thrust

2430

Eff. Thrust per fan

1650

Total Eff. Thrust

1650

Total Thrust

2430

Element

1000 SCR

41

Number per Pack

30

1230

Number of Pack

1

1230

Total Battery

1240

Servo

HS 80

18

Receiver

30

Total RC

102

Total Weight

2122

Total Payload

308

Current per Motor

40.0

Current per Pack

40.0



Last Updated on 10/17/97

By Fred

Email:jordan@ltssg3.epfl.ch